TIGER LED

TIGER LED

Series  of  escape  luminaires  TIGER  LED  has  an  up-to-date  light  source  LED 3,2W and is characterized by high efficiency in emergency mode – up to 270lm, which results in very large mounting distances between the luminaires:

  • up to 13,5m in escape route – min 1lx
  • up to 17,5m in open areas – min 0,5lx.

TIGER  LED  luminaires  are  very  easy  to  assemble.  There  are  four  types  of assembling: surface on a wall, surface on a ceiling; optionally recessed in a wall or ceiling with under plastering clips.

Fitting  can  be  configured  in  all  possible  ways:  suitable  for  central  battery system, central monitoring system, with an auto-test function or as a standard self contained option.

Description

 

 

 

 

MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 176 – 275VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1W, 2W, 3W LED
CHARGING:
BASIC: max. 24h
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
BASIC: 1h or 3h, Ni-Cd 3,6V batteries
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
II or III
IP RATING:
IP22
AMBIENT TEMPERATURE:
Self-contained:
ta: 0°C ÷ 40°C
CB:
ta: 0°C – +50°C
OPTIONS:
SE – non maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version

Tiger LED - tabelka_EN

LEGEND:
TL – fixture Tiger LED
E – electronic gear for BASIC self-contained fittings
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SE – non-maintained
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring
CB – central battery version
CBS – central battery for circuit monitoring
ADE – central battery with ADE address module
ADP – central battery with ADP address module – SMART technology
FZLV – central battery FZLV 24 VDC
TR – transparent polycarbonate cover
OP – opal polycarbonate cover