Key features
Benefits of evaporative cooling
How does it work
The outdoor hot air is moistened and cooled as it passes through water-soaked filters, then driven indoors at up to 12°C lower temperature. Thus, a constant flow of fresh and natural air is projected, which is introduced clean into the room, eliminating at the same time bad odours, germs and dust. This promotes the constant renewal of air that doesn’t recirculate, generating a healthy environment.
Installation example
Why Master?
Master evaporative systems adapt to our climate and are an excellent alternative to condition large spaces with low energy costs.
The installation is simple, since it’s sufficient with the positioning of the evaporative equipment on the roof or facade and connect it to a water supply and single-phase electric current. Thanks to its lightness, it doesn’t require cranes or large supporting structures for the installation and commissioning.
Self-management water cleaning system
Thanks to its electronic structure and components (electrovalve, drain valve and level sensors), Master equipment has an automated system for cleaning, emptying and filling water tank.
Pre-cool
The evaporative cooler enters in pre-cooling mode for one minute, just before the engine starts to operate, thus ensuring the cooling from the first moment.
Auto mode
With the previous adjustment of the required values of temperature and humidity, this mode allows to operate the equipment autonomously and efficiently by regulating its air flow rate, as well as water levels according to the values (Tº and %RH).
Auto clean
This function allows to set a period of time (hrs.) for the automation of units cleaning. Programmable period of time from 0 to 72hrs. The water drain valve opens allowing its exit and in this way the corresponding cleaning. After one minute the inlet solenoid valve opens, giving rise to a new water inlet in the tank. This self-cleaning mode is adjusted according to the measures and recommendations for prevention and control of Legionellosis.
Product specifications
Specifications | Units | BCM 311 |
---|---|---|
Cooling pad - total surface | dm³ | 306 |
Cooling pad size - 1 pc. | cm | 87 x 88 x 10 |
Air flow | m³/h | 31,000 |
Fan type | Axial | |
Fan speed | 12 | |
Power consumption | kW | 3 |
Power supply | V/Hz | 380/3ph/50-60 |
Air exit | mm | Down or top or side |
Tank capacity | l | 50 |
Water consumption | l/h | 30-50 |
Remote control integration | SM 4.0 | Yes |
Product size (l x w x h) | mm | 1280 x 1280 x 1170 |
Weight | kg | 86 |
Suitable for
- Agriculture
- Automotive
- Buildings and commercial spaces
- General industry and production