| Specifications | Units | RCV 320 |
|---|
| Maximum flow at 100Pa | V | m³/h | 320 |
| Maximum rated flow at 100Pa | Vmax | m³/h | 200 |
| Operating range DIBt | VDIBt | m³/h | 70 - 200 |
| Operating range Passivhaus at 100Pa | VPHI | m³/h | 70 - 160 |
| EN 13141-7 reference flow at 50Pa | VREF | m³/h | 140 |
| Performance | % | <2% (Class A1) |
| Thermal efficiency in accordance with PHI | ηSUP | % | 92 |
| Thermal efficiency in accordance with EN13141-7 | ηSUP | % | 90 |
| Leakage (external and internal) in accordance with EN 13141-7 | - | <2% (Class A1) |
| Filters in accordance with ISO16890 | - | ISO Coarse 75% (optional on supply: ePM1>50%) |
| Filters in accordance with EN779 | - | G4 (optional on supply: F7) |
| Installation surrounding temperature | tSURR | °C | -12 to +50 |
| Outdoor temperature without preheater installed | tODA | °C | -12* to +50 |
| Outdoor temperature with preheater installed | tODA | °C | -20 to +50 |
| Maximum absolute humidity of extract air | x | g/kg | 10 |
| Cabinet | - | 70 |
| Dimensions (without bracket) | mm | w x d x h | 600 x 603 x 526** |
| Spigots/ducts connections | Ømm | 8 pcs ø125 and 2 pcs oval (68 x 163) – female |
| Weight | kg | 35 |
| Thermal conductivity – polystyrene insulation | λ | W/mK | 0.031 |
| Heat transition figures – polystyrene insulation | U | W/m²K | U<1 |
| Fire classification of the polystyrene insulation | class | DIN 4102-1 class B2 |
| Drainage hose included | Ø/length | "/m | ø¾" – 1m |
| Cabinet colour | RAL | no paint/raw Alu-zinc |
| Electrical | - | |
| Voltage | U | V | 230 |
| Maximum power consumption (without/with preheater) | P | W | 170/1070 |
| Frequency | f | Hz | 50 |
| Protection class | - | IP21 |