Описание
MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (wall)
POWER SUPPLY:
self contained – 220÷240VAC/50÷60Hz
central battery – 220÷240VAC/50÷60Hz; 176 – 275VDC
central battery FZLV – 24VDC
LIGHT SOURCE:
SC30 3x1W; SC40 3W; SC60 2x3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
I or III
IP RATING:
IP40
VIEWING DISTANCE:
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
Self-contained:
ta: 0°C ÷ 40°C
CB:
ta: 0°C – +50°C
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
Aluminium body
Plexi glass
MOUNTING:
Surface (wall)
POWER SUPPLY:
self contained – 220÷240VAC/50÷60Hz
central battery – 220÷240VAC/50÷60Hz; 176 – 275VDC
central battery FZLV – 24VDC
LIGHT SOURCE:
SC30 3x1W; SC40 3W; SC60 2x3W LED
CHARGING:
STANDARD: max. 24h
PREMIUM: max. 12h; energy-saving electronic charger
AUTONOMY AND BATTERIES:
STANDARD: 1h or 3h, Ni-Cd 3,6V batteries
PREMIUM: 1h or 3h, LiFePO4 6,4V batteries
INSULATION CLASS:
I or III
IP RATING:
IP40
VIEWING DISTANCE:
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
Self-contained:
ta: 0°C ÷ 40°C
CB:
ta: 0°C – +50°C
OPTIONS:
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
AT – autotest
RU – Rubic UNA central monitoring
FZLV – central battery FZLV 24VDC
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charging
Deep discharge protection
III class of insulation of FZLV version
LEGEND:
SC30 – fixture Screen viewing distance 30m
SC40 – fixture Screen viewing distance 40m
SC60 – fixture Screen viewing distance 60m
C – electronic gear for STANDARD self-contained fittings
B – electronic gear for PREMIUM self-contained fittings
F – electronic gear for central battery fittings
Z – electronic gear for addressable central battery fittings
SA – maintained (with an option of connecting as non-maintained)
PT – manual test button
X – fitting without additional options
AT – autotest
RU – RUBIC UNA central monitoring system
CB – central battery version
CBS – central battery for circuit monitoring
ADP – central battery with ADP address module – SMART technology
ADE – central battery with ADE address module
FZLV – central battery FZLV 24 VDC