{"id":16219,"date":"2025-01-14T09:51:48","date_gmt":"2025-01-14T05:51:48","guid":{"rendered":"https:\/\/airsystems.ge\/shop\/?post_type=product&#038;p=16219"},"modified":"2025-03-30T17:55:31","modified_gmt":"2025-03-30T13:55:31","slug":"16219","status":"publish","type":"product","link":"https:\/\/airsystems.ge\/shop\/product\/16219\/","title":{"rendered":"Room air purifier TAC V+ in basalt gray\/black"},"content":{"rendered":"<table id=\"t066722b18bdb29\" class=\"tech\" cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr class=\"titlerow\">\n<th class=\"color titlerow-dropdown rotate-225deg\" colspan=\"3\">Technical data<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"headerrow\">\n<th colspan=\"3\">General information<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Article number<\/th>\n<td width=\"40%\">1.580.000.152<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Dust class<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">as per DIN EN 60335-2-69<\/th>\n<td width=\"40%\">H<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">as per DIN\u00a0EN\u00a01822 (ISO\u00a045H filter ISO\u00a029463)<\/th>\n<td width=\"40%\">H14<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">as per DIN\u00a0EN\u00a0779:2002<\/th>\n<td width=\"40%\">F7<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Air flow rate<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Max. air volume flow [m\u00b3\/h]<\/th>\n<td width=\"40%\">2,200<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Suitable for rooms sized up to\u00a0[m\u00b2\/m\u00b3] with H14\u00a0filter class<\/th>\n<td width=\"40%\">80 m\u00b2 \/200 m\u00b3<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Recommended amount of air for HighFlow filter with filter class H14\u00a0\u2264 [m\u00b3\/h]<\/th>\n<td width=\"40%\">1,200<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Recommended amount of air for HighFlow filter with filter class H13\u00a0\u2264 [m\u00b3\/h]]<\/th>\n<td width=\"40%\">1,800<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Recommended amount of air for Ultra HighFlow filter with filter class H14\u00a0\u2264 [m\u00b3\/h]<\/th>\n<td width=\"40%\">2,000<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Recommended amount of air for Ultra HighFlow filter with filter class H13\u00a0\u2264 [m\u00b3\/h]<\/th>\n<td width=\"40%\">2,200<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Electrical values<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Mains connection<\/th>\n<td width=\"40%\">220 &#8211; 240 V, 50\/60 Hz<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Power consumption without thermal decontamination at 900 m\u00b3 \/ h air volume [kW]<\/th>\n<td width=\"40%\">0.16<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Power consumption with thermal decontamination (60 min) [kW]<\/th>\n<td width=\"40%\">2.5<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Nominal current consumption [A]<\/th>\n<td width=\"40%\">11.3<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Recommended fusing [A]<\/th>\n<td width=\"40%\">13<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Electric connection<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Connection plug<\/th>\n<td width=\"40%\">CEE 7\/7, H07RN-F<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Cable length [m]<\/th>\n<td width=\"40%\">4<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Sound values<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">with sound protection hood &#8211; Distance 1 m<\/th>\n<td width=\"40%\">33 &#8211; 64 dB(A)<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">with sound protection hood and Ultra HighFlow filter &#8211; Distance 1 m<\/th>\n<td width=\"40%\">33 &#8211; 62 dB(A)<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Fan<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Radial<\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">axial<\/th>\n<td width=\"40%\"><\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">stages<\/th>\n<td width=\"40%\">7<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Safety feature<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Protection class<\/th>\n<td width=\"40%\">IP23<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Dimensions<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Length (packaging excluded) [mm]<\/th>\n<td width=\"40%\">690<\/td>\n<\/tr>\n<tr class=\"even\">\n<th width=\"30%\">Width (packaging excluded) [mm]<\/th>\n<td width=\"40%\">610<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">Height (packaging excluded) [mm]<\/th>\n<td width=\"40%\">1,300<\/td>\n<\/tr>\n<tr class=\"headerrow\">\n<th colspan=\"3\">Weight<\/th>\n<\/tr>\n<tr class=\"odd\">\n<th width=\"30%\">(packaging excluded) [kg]<\/th>\n<td width=\"40%\">89<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Room air purifier TAC V+ in basalt gray\/black<\/p>\n<p>The air purifier TAC V + reduces the dwell time and intensity of aerosol and suspended matter clouds directly at the installation site<\/p>\n<p>The zone air purifier TAC V + is an innovative solution for establishing clean air zones that are low in viruses and pollutants, wherever they are needed &#8211; a power connection is sufficient. Wherever this mobile air cleaner is placed, it creates a \u201cclean zone area\u201d of up to 320 cubic meters in volume, flushed with clean, filtered clean air, depending on the required air exchange rate.<\/p>\n<p>In this treatment zone, the ambient air remains largely free of germs, fine dust or other airborne microparticles, because the TAC V + enables the large-volume intake of contaminated room air with effective H14 HEPA filtering and a flexibly adjustable flushing of the zone, free of aerosol particles.<\/p>\n<p>In combination with the integrated F7 prefilter system, the Trotec H14-HEPA filter ensures the safe separation of airborne germs, viruses and dust, bacteria, spores or microfibers from paper such as textiles.<\/p>\n<p>The innovative combination of filter and decontamination technology is unique in the world and only available from Trotec:<\/p>\n<p>The TAC V + has a thermal self-regeneration function of the HEPA special filter, which automatically inactivates all viruses separated in the filter at regular intervals and thus 100% decontaminates the filter again.<\/p>\n<p>In this way, the TAC V + significantly and safely reduces an airborne infection risk in heavily frequented public areas and guarantees dust-free working conditions in work areas contaminated with dust:<\/p>\n<p>Protects customers, patients, guests and employees by significantly reducing the risk of infection<br \/>\nProtects employees from fine dust pollution in the workplace<br \/>\nProtects materials, electronics and machines from dirt and dust-related malfunctions<br \/>\nSome of the many convincing equipment advantages of the TAC V +<\/p>\n<p>Easy handling: Commissioning the TAC V + requires only a few simple steps. Timers, operating hours counters, filter level warning indicators and operating switches are installed to protect them from impact.<\/p>\n<p>Uniform distribution of clean air: The specific slat characteristics of the DualDecon blow-out tower with its vertical directionality ensure a uniform, zone-filling flushing with filtered clean air. With the optionally available flow stop panels, individual blow-out sides can also be blocked, for example with a wall-side blow-out direction.<\/p>\n<p>Thermal filter decontamination: Unique in the world and exclusive to Trotec:<br \/>\nThe TAC V + has an automatic thermal self-regeneration function of the HEPA special filter, which inactivates all viruses separated in the filter at regular intervals and thus 100% decontaminates the filter again.<\/p>\n<p>Robust and mobile: Thanks to stable wheels and an adjustable push handle, the robustly designed room air cleaner is ideal for quickly changing the place of use. Simply set it up, connect it to the mains and start the air pollution control process.<\/p>\n<p>Practical advantages:<\/p>\n<p>Permanent air pollution control and virus filtering in areas with high public traffic or densely populated areas<br \/>\nPermanent air pollution control, virus and fine dust filtering in working areas with increased fine dust pollution<br \/>\nUnique worldwide and exclusively at Trotec: Automatic filter regeneration through thermal virus decontamination of the specially developed, heat-resistant high-performance HEPA filter of class H14 with a degree of separation of 99.995% with a particle size of 0.1 to 0.2 \u03bcm<br \/>\n&#8220;Clean-Zones-Areas&#8221;: Establish safe rest and work zones with virus-free filtered breathing air &#8211; individually dimensioned depending on the number of devices and people as well as the set air exchange rate<br \/>\n&#8220;Plug &amp; Play&#8221; &#8211; set up, plug in, switch on, done. Room filtration independent of existing air conditioning and ventilation systems<br \/>\nEffective air filtering with F7 pre-filter and H14-HEPA main filter<br \/>\nFlow directions can be regulated using the Flowstop orifice to flood the clean air into the desired clean air zones as required<br \/>\nOptimally coordinated system components for flexible applications in the areas of virus and dust protection<br \/>\nSimple operation: Fully automatic, low-maintenance around-the-clock operation<br \/>\nResource-saving: 100% environmentally friendly, no chemicals, no installation effort<br \/>\nHigh quality materials and workmanship: &#8220;Made in Germany&#8221; &#8211; original Trotec fabrication, virus special filters with individual tests and test certificates<br \/>\nProtects your investment: Maximum profitability thanks to loss-free air cleaning directly at the installation site<br \/>\nFlexible placement: Always place the mobile TAC V + where it is needed<br \/>\nIllustrations may show special equipment or accessories that are not included in the basic price of the TAC V +.<\/p>\n<p>Scope of delivery:<br \/>\nTAC V + air purifier<br \/>\n1 x F7 prefilter<br \/>\n1 x H14 filter<\/p>\n<p>Please note that the Flowstop orifice is not included in the scope of delivery!<\/p>\n<p>Caution! Only use original replacement filters from Trotec. Only these are designed to fit your device, tested and heat resistant. Cheap replicas usually do not achieve the specified filter values or guarantee the air volumes for which your device is designed. When using cheap imitation filters to protect against infection from viruses, there may be a health hazard. The heat-resistant filter is heated to very high temperatures during thermal contamination, for which cheap replica filters are not designed. There is a risk of fire here! Therefore, for your own safety, only use original filters from Trotec.<\/p>\n","protected":false},"featured_media":16232,"template":"","meta":[],"product_brand":[],"product_cat":[114,520],"product_tag":[],"class_list":{"0":"post-16219","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-air-conditioner-dehumidifier-heater-ventilat","7":"product_cat-cleaning-air-purifier-dust-filter","9":"first","10":"instock","11":"sale","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/product\/16219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/media\/16232"}],"wp:attachment":[{"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/media?parent=16219"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/product_brand?post=16219"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/product_cat?post=16219"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/airsystems.ge\/shop\/wp-json\/wp\/v2\/product_tag?post=16219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}