Product specifications
| Specifications | Units | RCC 220P2 |
|---|---|---|
| Max. achievable flow at 100Pa | V100Pa | m³/h | 220 |
| Max. declared flow at 100Pa | Vmax.rated | m³/h | 120 |
| Recommended operating range | V | m³/h | 45-130 |
| EN 13141-7 reference flow at 50Pa | VREF | m³/h | 84 |
| Performance | ||
| Thermal efficiency in accordance with EN13141-7 | ηSUP | % | 86 |
| Leakage (external and internal) in accordance with EN13141-7 | % | <2% (Class A1) |
| Filters in accordance with ISO16890 | – | ISO Coarse 75% (optional optional on supply: ePM1>50% ) |
| Filters in accordance with EN779 | – | G4 (optional on supply: F7) |
| Installation ambient temperature | tSURR | °C | +12 to +45 |
| Outdoor temperature without preheater installed | tODA | °C | -12 to +45 |
| Outdoor temperature with preheater installed | tODA | °C | -20 to +45 |
| Maximum absolute humidity in extract air | x | g/kg | 10 |
| Cabinet | ||
| Dimensions (without wall bracket) | w x d x h | mm | 580 x 200 x 900 |
| Spigots/duct connections | Ømm | 8 x 125 – female |
| Weight | kg | 17 |
| Thermal conductivity – polystyrene insulation | λ | W/mK | 0.031 |
| Heat transition figures – polystyrene insulation | U | W/m²K | U<1 |
| Fire classification of the polystyrene insulation | class | DIN 4102-1 class B2 EN 13501 class E |
| Drainage hose | Ø/length | “/mm | 1/2 |
| Cabinet colour | RAL | Alu-zinc |
| Electrical | ||
| Voltage | U | V | 230 |
| Maximum power consumption without/with preheater | P | W | 173/1073 |
| Frequency | f | Hz | 50 |
| Protection class | – | IP21 |